Renyun-Z Lighting Busbar System(63-500A)

The Renyun lighting busbar is a power support product specifically designed for heavy industrial production workshops, with a rated operating current of 160A to 315A. Featuring a unique air-cooled wave heat dissipation structure, it effectively controls line temperature, extends service life, and reduces energy costs. Additionally, the product is equipped with the human-machine intelligent power operation and maintenance system that enables real-time monitoring and management of the busbar unit, promptly identifies power system issues, and ensures potential safety hazards are eliminated at the source. The system provides users with enhanced safety and reliability in power supply assurance.

    lighting busbar summary
    lighting busbar summary
    lighting busbar summary

    Component

    The left power box supplies power to the lighting, busbar through cables, while the right power box transmitspower from the lighting busbar to other circuits or receives power from cables on the right side. Both units aremounted at the ends of vertical components, secured with spring bolts, and feature 10 mm wire terminals withsealed covers.

    1、Left Power Box: RYM-Z1-63AA4                                         2.Right Power Box: RYM-Z1-63SL4
    3、Left End Sleeve:RYM-Z1-63FA2                                          4.RightTerminal Cover:RYM-Z1-63FL2
    POWERBOX
    The RYM-Z1-63JR4 can be cut to the required size.
    Through the connection ofthe flexible wire pipe between the left power box and the right power box,
    the bus can be turned at anyangle and bypassed obstacles
    FLEXIBLE JOINT

    Plug structural parts

    1、Hull
    2、Fixed Card
    3、Phase and neutralline contacts
    4、Protective wire contact
    5、Transparent display cover for optional phase (optional phase type)
    6、Mark (color corresponds to polarity)(non-selectable phase)
    7、Pre-wired cable
    STRUCTURE OF PLUG

    Vertical Applications

    Installed vertically, the same systems can be used for rising-mains applications, with tap-offs feeding individual floors. Certified fire barriers are available at points where the busbar passes through a floor slab. Protection devices such as fuses, switch fuses, or circuit breakers are located along the busbar run, reducing the need for large distribution boards and the large quantities of distribution cables running to and from installed equipment.
    Vertical Applications

    Characteristic

    All branch circuitconnectors are single-phase: L+N+PE;

    It can be pluggedin when thereis electricity and load;

    The live wire L and neutral wire N contacts are clamp-type, ensuring no stress on the plug's plastic base;

    lt has a device to preventwronginsertion and preventwrong connection;

    The PE protective conductor must be connected before the phase and neutral lines, contactingtheinnersurface ofthe busbar's straight component housing;

    Flame retardancyandinsulation of plug and socket housingand insulation parts.

    Lighting Busbar Areas of Use

    Production areas in factories

    Textile factories

    Iron-steel and Industrial glass factories

    Automotive and automotive sub-industries

    Malls

    Exhibition areas

    High rise buildings

    Hotels

    Hospitals

    Business Centres

    Data Centers

    Oil & Gas Factories

      Description

    • 01 Micro Power Busbar
      The RYM-Z2 series micro-power busbar trunkingsystemdeliversa current range of 30A to 500A,Featuringmodularcompatibility,mass produetion,compaetdesign,high capacity,shortinstallationcyeles,easyassembly/disassembly,non-combustibleconstruction,andlong service life, it ensures reliabledeployment ofpowerdistribution networks for diverseapplications.

      02 Workgroup switch/Fuse Box
      When used with micro power busbar,itenablesindependent control ofcircuits,Through scientific power planning,green electricity consumption can be achieved.

      03 Rotating Socket
      The unique powerextraction design makes powerextractionnolongercomplicated.It can quickly extractpower without disconnectingthecircuit or destroyingthe original circuit,avoidingthe common phenomenonofstoppingworkand production formaintenance,andgreatlyimprovingthe powerefficiencyand productionefficiency.

      04 LightingSystem
      With high-lumen LED lights, it can be used as alight sourceto reduce workshop wiring.

      05 Slide-out Power Outlet
      Thedesignallows seamless operation byslidingatanyposition alongthe busbar,makingit ideal for longworkbenchesin cuttingworkshops due to its uniquephysicalstructure,The absence oftraditional cablewiringenhances the socket's reliability and safety

      06 Support System
      tconsistsofthreemaincomponents:a suspension rod.an inclined rod,and a balance rod.After customization,it can be fixed at any height and form a reliableconnection structure.

      07 Connect/Disconnect Unit
      The maximum rated current can be up to 500A. as theconnectionandtransfer pointofeach section of bus bar.with fire resistance.antideformation and other

    System General Technical Parameters

    Product categories L/S7, L/S5, L/S5X, L4 busbar L5B, L5A busbar
    Minimum/maximum ambient temperature 24-hour average -5/+40/35℃ -5/+40/35℃
    Levels of protection IP40 IP40
    Surface preparation Passivation or electrostatic powder coating (as required by the user) Passivation or electrostatic powder coating (as required by the user)
    Sheathing material Aluminum Aluminum
    Outer shell color The specific colors of International Standard Gray (RAL7032, RAL7035) are determined based on user requirements The specific colors of International Standard Gray (RAL7032, RAL7035) are determined based on user requirements
    Rated insulation voltage Ui 400V 500V
    Rated operating voltage Ue 380V 400V
    Rated frequency f 50HZ 50HZ
    Rated current Ie 100A~30A 500A~100A
    Rated short-time current 8kA 12kA
    Rated peak current 12kA 24kA
    Conductor material 铜 Cu 铜 Cu
    Maximum installation spacing 1.4m 1.4m
    Outline dimension 50*70 90*315(L5A) / 54*80(L5B)
    Voltage category/contamination level Low pressure / 3 Low pressure / 3

    Images

    Dense Busbar System (1)
    Dense Busbar System (2)
    Dense Busbar System (3)

    TO KNOW MORE ABOUT Renyun, PLEASE CONTACT US!