inquiry
Leave Your Message

Custom Busway Manufacturer for Commercial and Industrial Projects

Renyun provides busbar trunking systems for power distribution in commercial buildings, industrial facilities and other electrical infrastructure projects. Explore our product range and request a quotation based on your project requirements.

Renyun (Hunan) Busbar Co., Ltd.
Turnkey Electrical Transmission & Distribution Since 2008
50,000 m² Smart Workshop Area
8 Lines Automated Assembly
Up to 6300A Rated Current Capability
12 Offices Global Engineering Service

Why Work with Renyun Busbar?

Established in 2008, Renyun specializes in power transmission and distribution solutions. Our company profile highlights a 50,000 m² production workshop and eight automated production lines. We support buyers in evaluating suitable busbar systems for their projects.

2008
Year Established
Over 15 years of dedicated manufacturing experience in low-voltage and medium-voltage busway engineering.
50,000 m²
Production Base
High-capacity manufacturing workshop featuring heavy stamping, CNC bending, and dust-free automated insulation lines.
8 Lines
Automated Production
Precision robotic assembly lines delivering strict dimensional consistency and high structural integrity.
12 Global
Service Hubs
Twelve direct sales and technical application offices worldwide to ensure rapid pre-sales review and post-sales installation guidance.

Precision Busbar Power Solutions for Demanding Project Environs

At Renyun, we engineer power distribution solutions that replace traditional high-loss cable runs with compact, high-efficiency busbar trunking systems. The company is committed to the research and development, production, sales, and service of busbars aiming to create a world-class brand.

Our engineering division cooperates closely with general contractors, EPC firms, and electrical consultants to evaluate load characteristics, physical routing constraints, seismic resistance specifications, and thermal performance requirements. Whether provisioning a 6300A main feeder or modular 100A plug-in data center racks, our systems ensure energy savings and operational safety.

  • T2 Pure Electrolytic Copper (≥99.99%)
  • Class B, F & H Thermal Insulation
  • Rugged Extruded Aluminum Alloy Enclosures
  • Verified IP54, IP65, IP68 Ingress Protection

530x530 (530×397)Modern Intelligent Manufacturing Facilities

Equipped with automatic copper bar polishing machines, insulation wrap lines, laser welding robots, and computer-controlled routine testing benches.

Explore Our Busway Product Range

Select from our comprehensive range of high-capacity sandwich compact busways, air-insulated trunking, mineral resin cast systems, and critical mission busbars engineered for reliable power transfer.

M7 Compact Busbar System(315-6300A)
Heavy-Duty Sandwich Design

M7 Compact Busbar System (315-6300A)

  • Current Rating: 315A - 6300A
  • Conductor: T2 Copper / Bimetal Al
  • Insulation: Class F (155°C) Polyester
  • Housing: Extruded Al-Mg Alloy
  • Application: Commercial complexes, heavy plant mains
S2 Compact Busbar System(400-1600A)
Medium Power Distribution

S2 Compact Busbar System (400-1600A)

  • Current Rating: 400A - 1600A
  • Voltage Rating: Up to 1000V
  • Protection Level: IP54 / IP65
  • Joint Structure: Single-bolt torque clamp
  • Application: Riser shafts, commercial floors, light industry
NHRYMC Fire-Resistant Compact Busbar System(400-2500A)
Fire Safety Certified

NHRYMC Fire-Resistant System (400-2500A)

  • Current Rating: 400A - 2500A
  • Fire Endurance: 950°C for 90-180 min
  • Insulation: Mica tape & ceramic composite
  • Flame Retardancy: Self-extinguishing (GB/T 19216)
  • Application: Emergency power, fire pumps, tunnels, subways
FSMC-RY Resin Cast Busbar System(400-6300A)
IP68 Submersible / Outdoor

FSMC-RY Resin Cast Busbar (400-6300A)

  • Current Rating: 400A - 6300A
  • Protection Index: IP68 / IK10 impact
  • Casting Resin: Epoxy resin with silica blend
  • Corrosion Class: Chemical, salt spray & UV immune
  • Application: Offshore platforms, chemical plants, trenches
K Air-Insulated Busbar System(315-5000A)
Air Gap Insulated

K Air-Insulated Busbar System (315-5000A)

  • Current Rating: 315A - 5000A
  • Insulation Media: Air clearance + modular spacer
  • Enclosure: Ventilated or non-ventilated steel/Al
  • Tap-off Units: Multi-point plug-in slots
  • Application: Industrial workshops, manufacturing halls
Common Box Enclosed Busbar System(800-3200A)
Phase Segregated / Enclosed

Common Box Enclosed Busbar (800-3200A)

  • Current Rating: 800A - 3200A
  • Voltage Range: Up to 35kV medium voltage
  • Housing Construction: Alloy plate shielding
  • Electrodynamic Withstand: High peak short-circuit limit
  • Application: Generator connections, substation transformers
XLMC-RY Data Center Busbar System(100-630A)
Hot-Swappable Server Track

XLMC-RY Data Center Busbar (100-630A)

  • Current Rating: 100A - 630A
  • Tap-off Flexibility: Plug-and-play under live load
  • Monitoring: Smart meter & thermal sensor ready
  • Configuration: Overhead rack-mounted raceway
  • Application: Hyperscale data centers, server racks
Z Lighting Busbar System(63-500A)
Modular Commercial Track

Z Lighting Busbar System (63-500A)

  • Current Rating: 63A - 500A
  • Poles Available: 2P, 4P, 5P options
  • Installation: Suspended / ceiling quick-clip
  • Flexibility: Moveable tap-off connectors
  • Application: Supermarkets, logistics warehouses, showrooms
M6 Compact Busbar System(315-5000A)
High Efficiency Sandwich

M6 Compact Busbar System (315-5000A)

  • Current Rating: 315A - 5000A
  • Impedance: Ultra-low reactive drop
  • Phase Configuration: 3P3W / 3P4W / 3P5W (200% Neutral)
  • Heat Dissipation: Direct enclosure radiation
  • Application: Commercial high-rise risers, manufacturing main feeders
Spray molding cable tray
Support & Routing Ancillary

Spray Molding Cable Tray

  • Surface Treatment: Electrostatic spray powder coat
  • Corrosion Resistance: High acid/alkali tolerance
  • Load Capacity: Heavy industrial standard
  • Profile Types: Perforated, trough, ladder types
  • Application: Control cable support, power station routing

Project Requirements & Customization Process

Share your rated current, voltage, installation layout, operating environment and project drawings. Our team can review the available product options and help identify a suitable configuration.

Technical Inputs Needed from Your Team

To ensure an accurate quotation and prevent site layout clashes during commissioning, our engineering department reviews the following key data points:

1

Electrical Ratings & Phase System

Rated operational current (315A to 6300A), operating voltage (400V/690V/up to 35kV), 3P3W, 3P4W, or 3P5W with 100% or 200% neutral capacity for non-linear harmonic loads.

2

Installation Routing & Architectural Drawings

Single-line diagrams (SLD), isometric physical routing plans, floor-to-floor shaft heights, transformer connection flange dimensions, and switchgear interface drawings.

3

Environmental & Ingress Conditions

Indoor cleanroom, commercial dry riser (IP54), humid manufacturing bay (IP65), outdoor weatherproof runs, or high-humidity marine/corrosive chemical conditions (IP68 Cast Resin).

4

Tap-off Branch Requirements

Quantity, location, and breaker amperage specs of plug-in tap-off boxes (32A to 1250A) for branch feeds without interrupting downstream busway continuity.

Step-by-Step Customization Roadmap

Clear engineering verification phases guarantee that the manufactured busbars match jobsite tolerances:

1

Schematic & BIM Model Cross-Check

Our engineers convert your 2D CAD or 3D Revit models into segmented busbar duct runs, calculating exact feeder section lengths, elbow bends, and expansion units.

2

Voltage Drop & Short-Circuit Verification

We model thermal rise and peak short-circuit electrodynamic withstand (Icw) based on your system transformer ratings to ensure full compliance before fabrication.

3

Automated Precision Manufacturing

Parts are processed across our 8 automated production lines, employing computer-controlled conductor cutting, Class F/H insulation winding, and torque-controlled casing assembly.

4

Factory Routine Testing & Numbered Packaging

Every single length passes high-voltage dielectric withstand, phase sequence, and contact resistance tests before tagged, waterproof crating for orderly jobsite assembly.

Applications and Project Experience

Engineered for diverse critical infrastructure segments. Renyun busbar systems are built to withstand intensive continuous electrical loads and harsh industrial operations.

Vertical riser trunking and distribution for high-rise corporate headquarters, multi-tenant financial towers, and mixed-use commercial hubs requiring minimal shaft space footprint.

Typical Scope: M7 / M6 Sandwich Busbar (800A - 3200A), floor-by-floor plug-in tap-off units with metering, spring riser hangers.

Overhead power delivery for automotive stamping lines, electronics fabrication cleanrooms, chemical production, and food processing facilities requiring flexible line retooling.

Typical Scope: K Series Air-Insulated & Compact M7 (1000A - 5000A), spray molding cable trays for control circuits.

Reliable power supplies for high-speed railway terminals, underground metro stations, airport concourses, and subterranean vehicular tunnels demanding strict fire integrity.

Typical Scope: NHRYMC Fire-Resistant Busway (400A - 2500A), Common Box enclosed busducts linking main transformer substations.

Power transmission across drilling rigs, floating production units (FPSO), coastal petrochemical yards, and dockyards subjected to saline atmosphere and mechanical vibrations.

Typical Scope: FSMC-RY Cast Resin Busbar System (IP68, 400A - 6300A), immune to salt spray, humidity, and chemical vapor exposure.

Quality Assurance & Technical Documentation

Every Renyun busbar system is subjected to standardized quality inspection protocols to ensure safety, thermal stability, and long-term durability in accordance with international electrical engineering directives.

Type-Tested to IEC 61439-6

Verified under accredited lab environments for temperature rise limits, dielectric properties, short-circuit withstand strength (Icw), protection circuit effectiveness, and structural clearances.

Ingress Protection (IP54 - IP68)

Formal lab verification certificates for dust-tight and moisture-protected designs. Enclosures prevent fine particulate contamination and high-pressure jet wash penetration.

Raw Material Metallurgical Testing

We enforce incoming inspection on all copper conductors, verifying ≥99.99% purity and electrical conductivity exceeding 98% IACS to minimize resistive losses and avoid hot spots.

Fire Safety & Smoke Density Reports

NHRYMC fire-resistant lines comply with ISO/GB fire endurance testing at continuous 950°C furnace exposure for up to 3 hours with zero circuit collapse or toxic fume generation.

ISO 9001, ISO 14001 & ISO 45001

Full manufacturing compliance certified under international quality, environmental stewardship, and occupational health management systems across our 50,000 m² campus.

Seismic & Mechanical Impact Testing

Structural validation up to IK10 impact resistance and certified seismic restraint capabilities ensuring continuity in earthquake-prone critical data and healthcare facilities.

Submit Your Project Requirements

Receive an engineered proposal, bill of materials estimation, and price quotation from our technical support team within 24 hours.

What types of busway systems do you manufacture?

Renyun engineers a complete spectrum of low-voltage and medium-voltage busways: M7 and M6 Sandwich Compact Busbar Systems (315A-6300A), S2 Medium Commercial Busways (400A-1600A), NHRYMC Fire-Resistant Systems, FSMC-RY Cast Resin IP68 Waterproof Busways, K Series Air-Insulated Busducts, Common Box Enclosed Busbars, XLMC-RY Data Center Modular Track Busbars, and Z Series Lighting Busbars.

Can I request a project quotation and custom engineering layout?

Yes. Our engineering division provides technical proposals, voltage drop estimations, and structural layout assessments. Simply share your single-line diagram (SLD), floor layout, or system parameters through our RFQ form or via direct email.

Direct Engineering & Commercial Contacts

WhatsApp: +86 13548971600