China Suppliers Renyun-Z Lighting Busbar System (63-500A) - High Efficiency Power Solution from Factory
Sizes of Rigid Conductors
16 A, 25 A, and 63 A
Core Components
The RYM-Z1-16EA403, RYM-Z1-25EA403, RYM-Z1-40EA403, and RYM-Z1-63EA403
Features
2-core or 4-core insulated busbars and comes in standard lengths
Power Box and Terminal Cover
The left power box supplies power to the lighting busbar through cables, while the right power box transmits power from the lighting busbar to other circuits or receives power from cables on the right side. Both units are mounted at the ends of vertical components, secured with spring bolts, and feature 10 mm wire terminals with sealed covers.
- 1. Left Power Box: RYM-Z1-63AA4
- 2. Right Power Box: RYM-Z1-63SL4
- 3. Left End Sleeve: RYM-Z1-63FA2
- 4. Right Terminal Cover: RYM-Z1-63FL2
Flexible Joint
The RYM-Z1-63JR4 can be cut to the required size. Through the connection of the flexible wire pipe between the left power box and the right power box, the bus can be turned at any angle and bypassed obstacles.
Plug Structural Parts
- 1. Hull
- 2. Fixed Card
- 3. Phase and neutral line contacts
- 4. Protective wire contact
- 5. Transparent display cover for optional phase (optional phase type)
- 6. Mark (color corresponds to polarity) (non-selectable phase)
- 7. Pre-wired cable
Vertical Applications
Installed vertically, the same systems can be used for rising-mains applications, with tap-offs feeding individual floors. Certified fire barriers are available at points where the busbar passes through a floor slab. Protection devices such as fuses, switch fuses, or circuit breakers are located along the busbar run, reducing the need for large distribution boards and the large quantities of distribution cables running to and from installed equipment.
Characteristic
- All branch circuit connectors are single-phase: L+N+PE;
- It can be plugged in when there is electricity and load;
- The live wire L and neutral wire N contacts are clamp-type, ensuring no stress on the plug's plastic base;
- It has a device to prevent wrong insertion and prevent wrong connection;
- The PE protective conductor must be connected before the phase and neutral lines, contacting the inner surface of the busbar's straight component housing;
- Flame retardancy and insulation of plug and socket housing and insulation parts.
Lighting Busbar Areas of Use
Frequently Asked Questions
What are the available conductor sizes for these lighting busbars?
The rigid conductors are available in standard sizes of 16 A, 25 A, and 63 A.
How do the power boxes manage electrical supply and distribution?
The left power box supplies power to the lighting busbar via cables, while the right power box transmits power from the busbar to other circuits or receives power from the right side.
Can the flexible joint be adjusted to bypass obstacles?
Yes, the RYM-Z1-63JR4 flexible joint can be cut to the required size, allowing the busbar to turn at any angle and easily bypass obstacles.
What safety features prevent incorrect plug connections?
The system features a dedicated physical device to prevent wrong insertion and wrong connection. Additionally, the PE protective conductor is designed to connect before the phase and neutral lines.
Can these busbars be used for vertical installations?
Yes, they can be installed vertically for rising-mains applications with tap-offs feeding individual floors. Certified fire barriers are available for floor-slab penetrations.
Where are these lighting busbar systems typically applied?
They are widely used in factories (production and textile), automotive industries, malls, exhibition areas, high-rise buildings, hotels, hospitals, business centers, data centers, and oil & gas facilities.