China Suppliers Factory Z Lighting Busbar System (63-500A) - Efficient Power Solution for Industrial Applications
System Overview & Specifications
Sizes of Rigid Conductors
16 A, 25 A, and 63 A
Core Components
The RYM-Z1-16EA403, RYM-Z1-25EA403, RYM-Z1-40EA403, and RYM-Z1-63EA403
Features
2-core or 4-core insulated busbars and comes in standard lengths
Component
Power Box and Terminal Cover
The left power box supplies power to the lighting busbar through cables, while the right power box transmits power from the lighting busbar to other circuits or receives power from cables on the right side. Both units are mounted at the ends of vertical components, secured with spring bolts, and feature 10 mm wire terminals with sealed covers.
1. Left Power Box: RYM-Z1-63AA4
2. Right Power Box: RYM-Z1-63SL4
3. Left End Sleeve: RYM-Z1-63FA2
4. Right Terminal Cover: RYM-Z1-63FL2
Flexible Joint
The RYM-Z1-63JR4 can be cut to the required size.
Through the connection of the flexible wire pipe between the left power box and the right power box, the bus can be turned at any angle and bypassed obstacles.
Plug Structural Parts & Applications
Plug Structural Parts
1. Hull
2. Fixed Card
3. Phase and neutral line contacts
4. Protective wire contact
5. Transparent display cover for optional phase (optional phase type)
6. Mark (color corresponds to polarity)(non-selectable phase)
7. Pre-wired cable
Vertical Applications
Installed vertically, the same systems can be used for rising-mains applications, with tap-offs feeding individual floors. Certified fire barriers are available at points where the busbar passes through a floor slab. Protection devices such as fuses, switch fuses, or circuit breakers are located along the busbar run, reducing the need for large distribution boards and the large quantities of distribution cables running to and from installed equipment.
Characteristic
All branch circuit connectors are single-phase: L+N+PE;
It can be plugged in when there is electricity and load;
The live wire L and neutral wire N contacts are clamp-type, ensuring no stress on the plug's plastic base;
It has a device to prevent wrong insertion and prevent wrong connection;
The PE protective conductor must be connected before the phase and neutral lines, contacting the inner surface of the busbar's straight component housing;
Flame retardancy and insulation of plug and socket housing and insulation parts.
Lighting Busbar Areas of Use
Frequently Asked Questions (FAQ)
What are the available sizes and current ratings for rigid conductors?
The rigid conductor lighting busbars are available in current ratings of 16 A, 25 A, and 63 A, designed with 2-core or 4-core insulated busbar options in standardized lengths.
Can tap-off units be plugged in while energized?
Yes, the system is engineered so that tap-offs can be safely plugged in even when electricity is live and load is present, supported by clamp-type contacts and strict safety interlocks.
How does the flexible joint assist during busbar installation?
The RYM-Z1-63JR4 flexible joint can be cut to custom lengths, bridging the left and right power boxes through flexible wire piping to allow the run to bend at any angle and easily bypass building obstacles.
What safety mechanism ensures proper grounding during plug insertion?
The PE protective conductor is designed to connect prior to the phase and neutral lines by directly contacting the inner surface of the busbar housing. The unit also includes dedicated devices to prevent incorrect insertion and polarity connection errors.
Can this busbar system be utilized for vertical rising-mains applications?
Yes, installed vertically, the system works for rising mains across multiple floors. Certified fire barriers can be installed at slab crossings, and localized protective devices eliminate the requirement for cumbersome centralized distribution boards.
Which industrial and commercial environments are ideal for this lighting busbar?
It is suitable for automotive plants, textile factories, steel and glass mills, malls, exhibition halls, high-rise buildings, data centers, hospitals, business centers, hotels, and oil & gas production facilities.