China RYM-Z Lighting Busbar System (63-500A) - Reliable Power Solutions from Top Suppliers and Factory

The RYM-Z lighting busbar is a robust power support solution tailored for heavy industrial production workshops in China. With a rated operating current ranging from 160A to 315A, this product features a distinctive air-cooled wave heat dissipation structure that effectively manages line temperature, prolongs service life, and minimizes energy costs. As one of the leading suppliers in the industry, our factory equips the RYM-Z busbar with an advanced human-machine intelligent power operation and maintenance system. This innovative capability allows for real-time monitoring and management of the busbar unit, quickly identifying any power system issues and addressing potential safety hazards at their source. By choosing the RYM-Z lighting busbar, users benefit from enhanced safety and reliability in power supply assurance, making it an essential choice for industrial applications in China

    Sizes of rigid conductors

    16 A, 25 A, and 63 A

    Core components

    The RYM-Z1-16EA403, RYM-Z1-25EA403, RYM-Z1-40EA403, and RYM-Z1-63EA403

    Features

    2-core or 4-core insulated busbars and comes in standard lengths

    lighting busbar summary

    Component Details

    Power Box and Terminal Cover

    The left power box supplies power to the lighting busbar through cables, while the right power box transmits power from the lighting busbar to other circuits or receives power from cables on the right side. Both units are mounted at the ends of vertical components, secured with spring bolts, and feature 10 mm wire terminals with sealed covers.

    1. Left Power Box: RYM-Z1-63AA4
    2. Right Power Box: RYM-Z1-63SL4
    3. Left End Sleeve: RYM-Z1-63FA2
    4. Right Terminal Cover: RYM-Z1-63FL2
    POWERBOX

    Flexible Joint

    The RYM-Z1-63JR4 can be cut to the required size. Through the connection of the flexible wire pipe between the left power box and the right power box, the bus can be turned at any angle and bypasses obstacles.

    FLEXIBLE JOINT

    Plug Structural Parts

    1. Hull
    2. Fixed Card
    3. Phase and neutral line contacts
    4. Protective wire contact
    5. Transparent display cover for optional phase (optional phase type)
    6. Mark (color corresponds to polarity)(non-selectable phase)
    7. Pre-wired cable
    STRUCTURE OF PLUG

    Vertical Applications

    Installed vertically, the same systems can be used for rising-mains applications, with tap-offs feeding individual floors. Certified fire barriers are available at points where the busbar passes through a floor slab. Protection devices such as fuses, switch fuses, or circuit breakers are located along the busbar run, reducing the need for large distribution boards and the large quantities of distribution cables running to and from installed equipment.

    Vertical Applications

    Characteristics

    All branch circuit connectors are single-phase: L+N+PE;
    It can be plugged in when there is electricity and load;
    The live wire L and neutral wire N contacts are clamp-type, ensuring no stress on the plug's plastic base;
    It has a device to prevent wrong insertion and prevent wrong connection;
    The PE protective conductor must be connected before the phase and neutral lines, contacting the inner surface of the busbar's straight component housing;
    Flame retardancy and insulation of plug and socket housing and insulation parts.

    Lighting Busbar Areas of Use

    Production areas in factories
    Textile factories
    Iron-steel and Industrial glass factories
    Automotive and automotive sub-industries
    Malls
    Exhibition areas
    High rise buildings
    Hotels
    Hospitals
    Business Centres
    Data Centers
    Oil & Gas Factories

    Frequently Asked Questions

    What sizes of rigid conductors are available for the lighting busbar?

    The lighting busbar system supports rigid conductor sizes of 16 A, 25 A, and 63 A.

    What are the core component models of the lighting busbar?

    The core component models include the RYM-Z1-16EA403, RYM-Z1-25EA403, RYM-Z1-40EA403, and RYM-Z1-63EA403.

    How does the Power Box and Terminal Cover work?

    The left power box supplies power to the lighting busbar via cables, while the right power box transmits power out to other circuits. Both are mounted at vertical ends with spring bolts and feature 10 mm wire terminals with sealed covers.

    What is the purpose of the Flexible Joint?

    The RYM-Z1-63JR4 flexible joint can be cut to size. It connects the left and right power boxes via a flexible wire pipe, allowing the busbar to turn at any angle and bypass obstacles.

    What safety mechanisms are built into the plug structural parts?

    The system features a device to prevent wrong insertion and connection. Additionally, the PE protective conductor is designed to connect before the phase and neutral lines make contact.

    Where are these lighting busbars commonly used?

    They are widely used in factory production areas, textile and glass factories, automotive industries, malls, exhibition halls, high-rise buildings, hotels, hospitals, business centers, data centers, and oil & gas facilities.