China Lighting Busbar System (63-500A) | Reliable Suppliers & Factory Solutions for Industrial Power Supply

The Renyun lighting busbar is a high-performance power support solution crafted specifically for heavy industrial production workshops, with a rated operating current of 160A to 315A. This innovative product features a state-of-the-art air-cooled wave heat dissipation structure that effectively manages line temperature, prolongs service life, and lowers energy costs. As one of the leading suppliers in China, we ensure that our busbar units come equipped with an advanced human-machine intelligent power operation and maintenance system. This system allows for real-time monitoring and management, swiftly identifying any power system issues and eliminating potential safety hazards at the source. By choosing Renyun, you gain enhanced safety and reliability in power supply assurance, backed by our dedicated factory standards and expertise.

    Rigid Conductors & Core Components

    Conductor Sizes

    Available in highly efficient current ratings of 16 A, 25 A, and 63 A to meet diverse power distribution demands.

    Core Components

    Precision engineered component systems including RYM-Z1-16EA403, RYM-Z1-25EA403, RYM-Z1-40EA403, and RYM-Z1-63EA403.

    Features

    2-core or 4-core insulated busbars, manufactured and supplied in standardized lengths for seamless modular installation.

    lighting busbar summary

    System Components

    Power Box & Terminal Cover

    The left power box supplies power to the lighting busbar through cables, while the right power box transmits power from the lighting busbar to other circuits or receives power from cables on the right side. Both units are mounted at the ends of vertical components, secured with spring bolts, and feature 10 mm wire terminals with sealed covers.

    • 1. Left Power Box: RYM-Z1-63AA4
    • 2. Right Power Box: RYM-Z1-63SL4
    • 3. Left End Sleeve: RYM-Z1-63FA2
    • 4. Right Terminal Cover: RYM-Z1-63FL2
    POWERBOX

    Flexible Joint

    The RYM-Z1-63JR4 can be cut to the required size. Through the connection of the flexible wire pipe between the left power box and the right power box, the bus can be turned at any angle and easily bypass obstacles.

    FLEXIBLE JOINT

    Plug & Installation Structure

    Plug Structural Parts

    • 1. Hull
    • 2. Fixed Card
    • 3. Phase and neutral line contacts
    • 4. Protective wire contact
    • 5. Transparent display cover for optional phase (optional phase type)
    • 6. Mark (color corresponds to polarity) (non-selectable phase)
    • 7. Pre-wired cable
    STRUCTURE OF PLUG

    Vertical Applications

    Installed vertically, the same systems can be used for rising-mains applications, with tap-offs feeding individual floors. Certified fire barriers are available at points where the busbar passes through a floor slab. Protection devices such as fuses, switch fuses, or circuit breakers are located along the busbar run, reducing the need for large distribution boards and the large quantities of distribution cables running to and from installed equipment.

    Vertical Applications

    System Characteristics

    • All branch circuit connectors are single-phase: L+N+PE.
    • It can be plugged in safely when there is active electricity and load.
    • The live wire L and neutral wire N contacts are clamp-type, ensuring no mechanical stress on the plug's plastic base.
    • Equipped with a specialized device to prevent wrong insertion and prevent incorrect connection.
    • The PE protective conductor must be connected before the phase and neutral lines, contacting the inner surface of the busbar's straight component housing.
    • High-standard flame retardancy and insulation performance of the plug, socket housing, and internal insulation parts.

    Lighting Busbar Areas of Use

    Production areas in factories
    Textile factories
    Iron-steel & glass factories
    Automotive & sub-industries
    Malls & retail centers
    Exhibition areas & halls
    High rise buildings
    Hotels & hospitality
    Hospitals & medical centers
    Business Centres & offices
    Data Centers
    Oil & Gas Factories

    Frequently Asked Questions (FAQ)

    What current ratings are available for these rigid conductors?

    The rigid conductors are available in standard current ratings of 16 A, 25 A, and 63 A to support various lighting and low-power application loads.

    Can the branch circuit plugs be inserted while the system is live?

    Yes, the system is designed to allow safe plug-in and branch connection even when there is active electricity and load on the busbar.

    How does the system prevent incorrect phase connection or wrong insertion?

    The busbar system is equipped with a dedicated mechanical keying/prevention device that physically prevents wrong insertion and incorrect polarity alignment.

    What safety sequence does the grounding (PE) wire follow during plug insertion?

    For enhanced safety, the PE protective conductor is engineered to make contact with the inner surface of the busbar's straight housing component before the phase and neutral lines connect.

    Can this lighting busbar system be installed vertically?

    Yes, the system is suitable for vertical installations, such as rising-mains applications feeding individual floors. Certified fire barriers are available for floor-slab penetrations.